SEA USA · Heavy-duty hydraulic swing operator

Super Full Tank. For the gates nothing else will move.

SEA's heaviest hydraulic swing operator, which SEA bills as the most powerful operator on the market. It comes in two strokes: 20″ for leaves up to 30 ft or 4,500 lb, and 40″ for leaves up to 40 ft or 5,500 lb at continuous duty.

Fig. 01 — Surface hydraulic swing operatorLeaf 00°
Drag to rotate · Scroll to open
    • Windy sites
    • Heavy-duty gates
    • High-security entrances
    • Condominium & industrial use
    • Up to 40 ft or 5,500 lb

    Two strokes · one platform

    Pick the stroke by the leaf.

    Both run on 120 V with the UNIGATE 2I inverter board, hydraulic slowdown, and bypass-valve anti-crush. The 40″ stroke carries the longest, heaviest leaves at continuous duty.

    Elevation · Stroke comparisonScroll to extend
    Two hydraulic cylinders drawn to scale: the 20-inch stroke rod extends half as far as the 40-inch stroke rod SFT 20″ 20″ STROKE · 30 FT / 4,500 LB SFT 40″ 40″ STROKE · 40 FT / 5,500 LB
    Super Full Tank 20″Heavy-duty
    Stroke20″
    Rod diameter1″
    Max leaf length30 ft
    Max leaf weight4,500 lb
    Cycles / hour70
    DutyCommercial-industrial
    Power120 V ±5% 50/60 Hz · 540 W
    Max opening angle90° / 120°
    Protection classIP55
    SlowdownHydraulic
    Anti-crushingBypass / electronic
    Operating temp−4°F to 131°F
    Battery backupSTAR 400/800

    Rated max length or max weight; the combination is confirmed at spec review.

    Super Full Tank 40″Continuous duty
    Stroke40″
    Rod diameter1″
    Max leaf length40 ft
    Max leaf weight5,500 lb
    Duty cycles100% (UNIGATE)
    DutyCommercial-industrial
    Power120 V ±5% 50/60 Hz · 540 W
    Max opening angle90° / 120°
    Protection classIP55
    SlowdownHydraulic
    Anti-crushingBypass / electronic
    ConfigurationAll-in or split (piston + pump)
    Battery backupSTAR 400/800

    Rated max length or max weight; the combination is confirmed at spec review.

    Where it sits in the lineup

    Put your leaf on the chart.

    The Super Full Tank's rated maximums are the dashed boxes. If a smaller operator covers your gate, the tool will say so, and we'll quote that one instead.

    Envelope

    Construction

    Machined aluminum, running in oil.

    MechanicalBuild
    • Front and back flanges in solid machined aluminumMounting
    • Standard oscillating aluminum back fixing forkMounting
    • Round joint for stroke adjustmentSetup
    • Hydraulic distributor machined from aluminum barHydraulics
    • Oil lubrication of all mechanical componentsHydraulics
    • All-aluminum structure, high-resistance anodizedFinish
    Safety & securityOperation
    • Anti-crush through bypass valves for max thrust adjustmentSafety
    • Hydraulic slowdown for a controlled approachSafety
    • AC version locks in opening and closingSecurity
    • Release protected by a metal lock, keyed from insideSecurity
    • STAR 400/800 battery backup with fan coolingOutage
    • Entrapment devices scoped against UL 325 for the siteSpec

    Control · UNIGATE 2I

    An inverter board, pre-wired.

    The Super Full Tank runs on SEA's UNIGATE 2I inverter control, supplied in a pre-wired box (15″ × 16″ × 6″). One model covers 90 V to 265 V input.

    UNIGATE 2I · Integrated functionsInverter
    • Digital control with LCD displaySetup
    • Adjustable speed, acceleration and decelerationMotion
    • Continuous motor cycles, high strength in slowdownDuty
    • Obstacle reverse managementSafety
    • 2 relay contacts, 2 programmable GPIO outputsI/O
    • PROBE heater card for low temperaturesClimate
    • Timer with buffer battery and 2 time bandsSchedule
    • Drives 2 motors (2 FV inverters) or 4 with PM modulesScale

    Installer pricing

    Quote a heavy gate. Start with the leaf.

    Send the leaf length, weight, site conditions and cycle count. We'll confirm the stroke, the configuration and the safety devices before anything ships.

    • ALeaf length and weight, single or double
    • BWind exposure and site security requirements
    • CExpected cycles per day
    • DYour role: installer, GC, facilities, or specifier